THB Medical Supplies/Orthopaedic catalogue

0513 products

Arthroplasty Implants & Instruments

Prostheses that replace a damaged joint surface, with the instruments needed to prepare bone and seat the implant.

13 products in this range. Every item carries a THB item code — quote the code, size and material.

THB OR-100

Thompson Prosthesis

Cemented hip hemiarthroplasty for displaced femoral neck fractures in elderly patients.

SizeHead 37 – 53 mmMaterialStainless Steel
THB OR-101

Austin Moore Prosthesis

Uncemented fenestrated-stem hip hemiarthroplasty.

SizeHead 37 – 53 mmMaterialStainless Steel
THB OR-102

Bipolar Prosthesis — Fenestrated

Dual-mobility head that reduces acetabular wear; uncemented stem.

SizeHead 37 – 53 mmMaterialStainless Steel
THB OR-103

Bipolar Prosthesis — Non-Fenestrated

Bipolar head with solid stem, for cemented use.

SizeHead 37 – 53 mmMaterialStainless Steel
THB OR-104

Shoulder Prosthesis

Humeral head replacement for complex proximal humerus fractures and arthritis.

SizeHead 35 – 43 mmMaterialStainless Steel
THB OR-105

Elbow Prosthesis

Linked (hinged) total elbow replacement.

SizeOn requestMaterialStainless Steel
THB OR-106

Radial Head Prosthesis

Replaces the radial head after unreconstructable fractures.

SizeOn requestMaterialStainless Steel
THB OR-107

Head Impactor, Nylon Faced

Seats the prosthetic head without scratching its surface.

SizeInstrumentMaterialStainless Steel
THB OR-108

Rasp — assorted sizes

Shapes the femoral canal to receive the stem.

SizeInstrumentMaterialStainless Steel
THB OR-109

Head Extractor (Judet)

Corkscrew extractor to remove the fractured femoral head.

SizeInstrumentMaterialStainless Steel
THB OR-110

Head Gauge Set

Measures the removed head to choose the right prosthesis size.

SizeInstrumentMaterialStainless Steel
THB OR-111

Box Osteotome (Hollow Chisel)

Opens the femoral canal entry point.

SizeInstrumentMaterialStainless Steel
THB OR-112

Murphy Skid

Lever that guides the prosthetic head into the acetabulum.

SizeInstrumentMaterialStainless Steel
Implant selection, sizing and surgical technique are the responsibility of the treating surgeon. Specifications may change without notice; please confirm current availability before surgery.

Request a quotation

Send the item code, size or hole count, material and quantity. We confirm stock and send a written quotation, then deliver to your hospital or clinic.

Requisition

Reply within one working day

Bulk and tender enquiries welcome. Institutional credit terms available on approval.

Requisition0